Supported Devices

warning

The GoodWe only supports RS485 connection. No Modbus TCP support is available.

Device TypeModbus TCP (Ethernet)RS485Curtailment
ES Series
S-BP Series
HT Series
MT Series
KT Series
DT Series
SMT Series
EH Series
ET Series
BT Series
BH Series

Configuration

1: Connecting the RS485

1a Connect the RS485 strings between the GoodWe inverter and the Eniris controller. As you may see on this scheme, you coult connect the

Image

2: SolarGo Settings

StepImage
2a. Connect to the inverter’s WiFi and open the SolarGo app.Image
2b. Click More.Image
2c. Click Advanced Setting (you can find the password in the SolarGo manual).Image
2d. Select Grid Parameter Setting.Image
2e. Turn off Power Limit (If it is on, power from the battery cannot be fed into the grid).Image
2f. Go back and click Cancel (these settings will be saved anyway, no restart is needed).Image

3: Battery Settings in SolarGo.

StepImage
3a. Select Battery Setting.Image
3b. Turn off SOC Protection.Image
3c. Go back and click Cancel (these settings will be saved anyway, no restart is needed).Image

TCP Connection

It has been reported to work with GoodWe ET, EH, BT, BH, ES, EM, BP, DT, MS, D-NS, and XS families of inverters but this is not supported.

Wiring

If you have multiple goodwe devices it is possible to change adresses seperately for each device. Or you can daisy chain them. (https://docs.eniris.be/wiring-best-practices/#wiring)