Sofar logo
Sofar logo
Accesorios
AplicaciónAvisos de seguridad, mantenimiento y legalesCertificados
Configuración de la A a la Z
ControladorDirectrices de cableado y conectividad
Dispositivos
Bomba de Calor
Caldera
Cargas conmutable
Estación de Carga para Vehículos Eléctricos
Inversores Híbridos FV y de Batería
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngularAPsystems
Autarco
Batería AtepsBattlinkBeauventC-BateríaCellpowerChisajeDanfossDeltaDEYEDibujarDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEquipo EPEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inversores DMEGCInversores ESYInversores Fotovoltaicos, Híbridos y de Batería AnklousInversores FV, Híbridos y de Batería DET PoweriWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerReacondicionamientoRegitecRenonSAJSchneider SunEzySchucoSCUSE2200H a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Medidor de agua
Medidor de Energía
Medidor de Gas
Nube
Nuevas integraciones
Plc
Especificaciones
Específico del Cliente
Inicio rápidoInstalaciónLEDs de estadoLicenciaRed
Resolución de problemas
Señales Externas
Tiempo de respuesta del control
DispositivosInversores Híbridos FV y de Batería
logo

Dispositivos compatibles

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Inversor híbrido trifásicoSUNSYNK-12K-SG04LP3, SUNSYNK-50K-SG01HP3-EU-BM4✅✅✅

Cableado

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Image 1
Image 1
Image 1

Configuración

Advertencia
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Vaya a “Pantalla Principal” >> “Configuración del Sistema” >> “Función Avanzada.”

  • El Modbus SN debe configurarse con un número entre 1 y 247. ¡No seleccione 0! Tenga en cuenta que si hay varios dispositivos en el bus RS485, cada uno debe tener un número único. Esta es la dirección.
  • Debe estar marcado como esclavo.
  • Solo cuando un medidor adicional esté conectado directamente al inversor debe marcarse “EX_meter For CT”. Si solo hay un medidor en paralelo con el Sofar EMS debe estar desmarcado.
  • Asegúrese de que las siguientes configuraciones sean correctas: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"
Image 1

Powerstack

Previous Page

Sunwaytech

Next Page

On this page

Dispositivos compatiblesCableadoRS485Configuración