iWell Cube Battery
Supported Devices
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| iWell Cube Battery (Experimental) | Cube Series | ✅ | ❌ | ✅ |

Wiring
The Sofar EMS communicates with the iWell Cube battery system using Modbus TCP (Ethernet).
Connect the Ethernet (LAN) port of the battery system to the same network as the Sofar EMS.
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | Sofar EMS model OM1 | Sofar EMS model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Ethernet (TCP/IP) Port | RS485 A | RS485_POS | RS485 A | TX+ |
| Port Number | RS485 B | RS485_NEG | RS485 B | TX- |
| Connection Type | RS GND | GND | Not available | G |
tipp
Ensure both the Sofar EMS and the iWell Cube battery are in the same IP subnet
(e.g. 192.168.1.xxx) and can communicate over port 1025.
warnung
The iWell Cube Modbus TCP interface is active only when the battery system is powered on and initialized.
Do not connect to inactive units or during firmware updates.