| currentL1_A | Phase 1 (Line 1) current | Ampere (A) | - evChargerMetrics
- heatPumpMetrics
- boilerMetrics
- switchedLoadMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- submeteringMetrics
- batteryMetrics
| |
| currentL2_A | Phase 2 (Line 2) current | Ampere (A) | - evChargerMetrics
- heatPumpMetrics
- boilerMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- installationMetrics (only rp_one_m)
- submeteringMetrics
- batteryMetrics
| |
| currentL3_A | Phase 3 (Line 3) current | Ampere (A) | - evChargerMetrics
- heatPumpMetrics
- boilerMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- installationMetrics (only rp_one_m)
- submeteringMetrics
- batteryMetrics
| |
| currentN_A | Neutral current | Ampere (A) | - evChargerMetrics
- hybridInverterMetrics
- submeteringMetrics
| rp_one_m |
| voltageL1N_V | Phase 1 to Neutral voltage (Phase Voltage) | Volt (V) | - evChargerMetrics
- heatPumpMetrics (only rp_one_m)
- boilerMetrics (only rp_one_m or rp_ten_m)
- switchedLoadMetrics (only rp_one_m or rp_ten_m)
- solarInverterMetrics
- solarOptimizerMetrics (only rp_one_m or rp_ten_m)
- hybridInverterMetrics (only rp_one_m or rp_ten_m)
- submeteringMetrics (only rp_one_m or rp_ten_m)
- batteryMetrics (only rp_one_m or rp_ten_m)
| |
| voltageL2N_V | Phase 2 to Neutral voltage (Phase Voltage) | Volt (V) | - evChargerMetrics
- boilerMetrics (only rp_one_m or rp_ten_m)
- solarInverterMetrics (only rp_one_m or rp_ten_m)
- solarOptimizerMetrics (only rp_one_m or rp_ten_m)
- hybridInverterMetrics (only rp_one_m or rp_ten_m)
- submeteringMetrics (only rp_one_m or rp_ten_m)
- batteryMetrics (only rp_one_m or rp_ten_m)
| |
| voltageL3N_V | Phase 3 to Neutral voltage (Phase Voltage) | Volt (V) | - evChargerMetrics
- boilerMetrics (only rp_one_m or rp_ten_m)
- solarInverterMetrics (only rp_one_m or rp_ten_m)
- solarOptimizerMetrics (only rp_one_m or rp_ten_m)
- hybridInverterMetrics (only rp_one_m or rp_ten_m)
- submeteringMetrics (only rp_one_m or rp_ten_m)
- batteryMetrics (only rp_one_m or rp_ten_m)
| |
| voltageL1L2_V | Line-to-Line voltage between Phase 1 and Phase 2 | Volt (V) | - evChargerMetrics
- solarInverterMetrics
- solarOptimizerMetrics (only rp_one_m)
- hybridInverterMetrics
- submeteringMetrics
- batteryMetrics
| |
| voltageL2L3_V | Line-to-Line voltage between Phase 2 and Phase 3 | Volt (V) | - evChargerMetrics
- solarInverterMetrics
- solarOptimizerMetrics (only rp_one_m)
- hybridInverterMetrics
- submeteringMetrics
- batteryMetrics
| |
| voltageL3L1_V | Line-to-Line voltage between Phase 3 and Phase 1 | Volt (V) | - evChargerMetrics
- solarInverterMetrics
- solarOptimizerMetrics (only rp_one_m)
- hybridInverterMetrics
- submeteringMetrics
- batteryMetrics
| |
| frequency_Hz | System frequency | Hertz (Hz) | - evChargerMetrics
- boilerMetrics
- switchedLoadMetrics
- solarInverterMetrics
- hybridInverterMetrics
- submeteringMetrics
| |
| powerFactorTot | Total power factor | - | - evChargerMetrics
- solarInverterMetrics
- hybridInverterMetrics
- submeteringMetrics
| |
| powerFactorL1 | Phase 1 power factor | - | - hybridInverterMetrics
- submeteringMetrics
| rp_one_m |
| powerFactorL2 | Phase 2 power factor | - | - hybridInverterMetrics
- submeteringMetrics
| rp_one_m |
| powerFactorL3 | Phase 3 power factor | - | - hybridInverterMetrics
- submeteringMetrics
| rp_one_m |
| voltageDC_V | DC voltage | Volt (V) | - evChargerMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- solarStringMetrics
- batteryMetrics
| |
| currentDC_A | DC current | Ampere (A) | - evChargerMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- solarStringMetrics
- batteryMetrics
| |
| status | Device status (e.g. On, Off, Error) | - | - evChargerMetrics
- heatPumpMetrics
- boilerMetrics
- solarInverterMetrics (only rp_one_m)
- hybridInverterMetrics
- installationMetrics (only rp_one_m)
| |
| operationMode | Device operation mode | - | - evChargerMetrics (only rp_one_m and rp_ten_m)
- heatPumpMetrics
- boilerMetrics
- switchedLoadMetrics
- solarInverterMetrics
- solarOptimizerMetrics
- hybridInverterMetrics
- batteryMetrics
| |
| stateOfCharge_frac | State of Charge (SoC) | fraction (number between 0 and 1) | - evChargerMetrics
- hybridInverterMetrics
- batteryMetrics
| |
| stateOfHealth_frac | State of Health (SoH) | fraction (number between 0 and 1) | batteryMetrics | rp_one_m |
| childrenStorageStateOfCharge_frac | Average State of Charge (SoC) of all connected batteries at a particular site. | fraction (number between 0 and 1) | submeteringMetrics | |
| batteryCurrent_A | Real-time current to/from the battery | Ampere (A) | batteryMetrics | |
| batteryVoltage_V | Real-time voltage of the battery | Volt (V) | batteryMetrics | |
| evRequiringCharge | Indicates whether an EV is connected and requires a charge | True or False | evChargerMetrics | |
| setpoint_W | External signal power setpoint | Watt (W) | externalSignalMetrics | |
| strategy | External signal strategy | - | externalSignalMetrics | |
| signalActive | Is an external signal active or not | 0 or 1 | externalSignalMetrics | |
| reacPowerSetpoint_VAr | Reactive power setpoint | Volt-Ampere reactive (VAr) | externalSignalMetrics | |
| importLimit_W | Import power limit command for a particular site. | Watt (W) | externalSignalMetrics | |
| exportLimit_W | Export power limit command for a particular site. | Watt (W) | externalSignalMetrics | |