Sofar logo
Sofar logo
Acessórios
AplicativoAvisos de segurança, manutenção e legaisCertificados
Configuração de A a Z
ControladorDiretrizes para fiação e conectividade
Dispositivos
Bomba de Calor
Caldeira
Cargas Comutadas
Estação de Carregamento para Veículos Elétricos
Inversores Híbridos Fotovoltaicos e de Bateria
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAPsystems
Autarco
Bateria AtepsBateria-CBeauventCellpowerDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEquipamento EPEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGravaçãoGreener / Alfen
Growatt
Growatt Série MINSérie Growatt MICSérie Growatt MIDSérie Growatt MODSérie Growatt SPASérie Growatt SPHSérie Growatt UESérie Growatt WIT
HiteHithium
Huawei
Hypontech
Hyxipower
Inversores DMEGCInversores ESYInversores Fotovoltaicos, Híbridos e de Bateria AnklousInversores Fotovoltaicos, Híbridos e de Bateria DET PoweriWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRecondicionamentoRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H até SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Medidor de Água
Medidor de Energia
Medidor de Gás
Novas integrações
Nuvem
Plc
Especificações
Específico para o Cliente
Início RápidoInstalaçãoLEDs de StatusLicençaRede
Resolução de Problemas
Sinais Externos
Tempo de resposta do controle
DispositivosInversores Híbridos Fotovoltaicos e de BateriaGrowatt
logo

Dispositivos Suportados

Device TypeModbus TCP (Ethernet)RS485Curtailment
MIC 600TL-X❌✅
MIC 750TL-X✅
MIC 1000TL-X
MIC 1500TL-X
MIC 2000TL-X
MIC 2500TL-X
MIC 3000TL-X
MIC 3300TL-X
Image 1

Cabeamento

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1RS485 ARS485_POSRS485 ATX+
RS485 B1RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG

Configuração

Aviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Por padrão, o inversor está configurado para o endereço 1. Isso pode ser alterado via o menu de configurações do inversor. Isso é necessário apenas se vários dispositivos estiverem conectados ao barramento de comunicação RS485.

Você pode alterar o endereço do inversor pelo controle por toque. Funciona da seguinte forma:

Controle por toqueImpacto
Toque uma vezMuda o display ou número + 1
Toque duas vezesEntrar ou confirmar
Toque três vezesMenu anterior
Mantenha tocado por 5 segundos
  • Confirma a configuração do país ou número.
  • Restaura o valor padrão.

Altere o endereço acessando o menu "Set Comaddr" como mostrado na imagem à esquerda ou acima. Defina o endereço para um valor único. Veja o Capítulo 7 do manual do inversor para mais informações.

Growatt Série MIN

Previous Page

Série Growatt MID

Next Page