Sofar logo
Sofar logo
AppCertifikater
Eksterne Signaler
EMS
Enheder
Elbilopladningsstation
Energimåler
ABBAccuenergyAcrelAlgodueBilagBMR
Carlo Gavazzi
ChargeeChintCloud-målerdataDornscheidt
Eastron
Eniris
FluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupKlar til SmartgridLandis+GyrLegrandLitiotM-BusMetcomP1ApiPhoenix-ContactPilotSagemcom
Schneider
ComPact NSXIEM 2100 SerieIEM 2100 SerienIEM 3000 SerienMasterPact MTZPM 800 SeriePM 3250PM 5000 SeriePM 8000PowerTag Energi
Self configured energy meterSeneca S604SessyShelly Energi målereSiemensSmappeeSocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerWhatWattYouLessZendure P1 MålerZiv
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
EnhederEnergimålerSchneider

Schneider-Electric IEM 2100 Serien Energimålere

logo

Understøttede enheder

IEM 2100-serien er enfasede energimålere.

Device TypeModbus TCP (Ethernet)RS485
Schneider-Electric iEM 2100 Series❌✅
Schneider-Electric iEM 2150
Schneider-Electric iEM 2155
Schneider iEM 2150

Tilslutning

IEM 2100-serien kommunikerer via Modbus RTU over RS485.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
D1 (+)RS485 ARS485_POSRS485 ATX+
D0 (-)RS485 BRS485_NEGRS485 BTX-
0V / ShieldRS GNDGNDNot availableG

Se venligst enhedens manual for de nøjagtige pin-lokationer, da disse kan variere lidt mellem specifikke undermodeller (f.eks. iEM2150 vs iEM2155).

Konfiguration

Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Kommunikationsindstillinger

Sørg for, at enhedens indstillinger matcher driverens kapaciteter som defineret nedenfor:

  • Baudhastighed: 9600, 19200 eller 38400 (Standard er ofte 19200)
  • Paritet: Jævn, Ulige eller Ingen
  • Stopbits: 1
  • Databits: 8

Tjek enhedens manual for, hvordan du går ind i energimålerens konfigurationsmenu for at sætte Modbus-adressen og baudhastigheden.

ComPact NSX

Previous Page

IEM 2100 Serien

Schneider-Electric IEM 2100 Serien Energi Målere

On this page

Understøttede enhederTilslutningKonfigurationKommunikationsindstillinger