Sofar logo
Sofar logo
AppCertifikater
Eksterne Signaler
EMS
Enheder
Elbilopladningsstation
Energimåler
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
a-TroniXABB, FIMERADS-TecAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid og Batteri InvertereAPsystemsAteps Batteri
Autarco
BattlinkBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid og Batteri InvertereDEYEDiehl-AkoDMEGC InvertereDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UdstyrESY InvertereEVEFairlandFortonaForud for
Foxess
FraxFroniusGoodWeGotionGrønnere / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoveringRitarSAJSchneider SunEzySchucoSCUSE2200H til SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
EnhederPv Hybrid- og batteri-invertere
logo

Understøttede enheder

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Single Phase LV Hybrid Inverters (SG0XLP1-EU)SUN-3/3.6/5/6/7/7.6/8/10/12K❌✅❌
Three Phase LV Hybrid Inverters (SG0XLP3-EU)SUN-3/4/5/6/8/10/12/14/15/16/18/20K
Three Phase HV Hybrid Inverters (SG0XHP3-EU)SUN-5/6/8/10/12/15/20/25/29.9/30/35/40/50/60/70/75/80K
Single Phase String Inverters (G0XP1-EU)SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4/4.2/4.6/5/5.2/6/6.2/7/7.5/8/9/10/10.5K
Three Phase String Inverters (G0XP3-EU)SUN-3/4/5/6/7/8/9/10/12/15/18/20/22/23/25/30/35/36/40/45/50/60/70/75/80/90/100/120/125/130/135/136K

Ledningsføring

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Image 1
Image 1
Image 1

Konfiguration

Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Gå til "Main Screen" >> "System Settings" >> "Advanced Function."

  • Modbus SN skal sættes til et tal mellem 1 og 247. Vælg ikke 0!! Bemærk, at hvis der er flere enheder på RS485-bussen, skal hver tildeles et unikt nummer. Dette er adressen.
  • Slave skal være markeret.
  • Kun når en ekstra måler er tilsluttet direkte til inverteren, skal "EX_meter For CT" markeres. Hvis der kun er en måler parallelt med Sofar EMS, skal det være afmarkeret.
  • Sørg for, at følgende indstillinger er korrekte: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"