Sofar logo
Sofar logo
AppCertifikater
Eksterne Signaler
EMS
Enheder
Elbilopladningsstation
Energimåler
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
a-TroniXABB, FIMERADS-TecAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid og Batteri InvertereAPsystemsAteps Batteri
Autarco
BattlinkBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid og Batteri InvertereDEYEDiehl-AkoDMEGC InvertereDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UdstyrESY InvertereEVEFairlandFortonaForud for
Foxess
FraxFroniusGoodWeGotionGrønnere / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoveringRitarSAJSchneider SunEzySchucoSCUSE2200H til SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
EnhederPv Hybrid- og batteri-invertere

Regitec Invertere

Regitec

Understøttede Enheder

The Sofar EMS understøtter Regitec Hybrid invertere via både Modbus TCP (Ethernet) og Modbus RTU (RS485).

Device TypeModbus TCP (Ethernet)RS485
Regitec Hybrid Inverter✅✅

Kabelføring

Ethernet

For korrekt ethernet-kabling: Følg vejledningen for ethernet-kabling.

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
ARS485 ARS485_POSRS485 ATX+
BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG
Note
Note

Sørg for, at afslutningsmodstanden er korrekt sat, hvis inverteren er i enden af RS485-bussen.

Advarsel
Advarsel

Regitec-driveren er strengt konfigureret til en Baud Rate på 9600. Sørg for, at inverteren ikke er sat til 19200 eller 115200, da dette vil forhindre kommunikation.