Sofar logo
Sofar logo
AppCertifikater
Eksterne Signaler
EMS
Enheder
Elbilopladningsstation
Energimåler
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
a-TroniXABB, FIMERADS-TecAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid og Batteri InvertereAPsystemsAteps Batteri
Autarco
BattlinkBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid og Batteri InvertereDEYEDiehl-AkoDMEGC InvertereDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UdstyrESY InvertereEVEFairlandFortonaForud for
Foxess
FraxFroniusGoodWeGotionGrønnere / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoveringRitarSAJSchneider SunEzySchucoSCUSE2200H til SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
EnhederPv Hybrid- og batteri-invertere
logo

Dyness Invertere

Vigtigt
Vigtigt

Integrationen understøttes i øjeblikket op til en opladningsstatus grænse på 95%. Dette skyldes, at batteriet kan stoppe med at reagere på sætpunktet, når opladningsstatus overstiger 95%, på grund af batteristyringssystemets handlinger. Vi arbejder på at løse dette problem sammen med Dyness og andre partnere.

Understøttede Enheder

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
EC100100kWh✅✅✅
DH100F71~100kWh
DH200F100kW/215kWh
DH200Y100kW/232kWh❌

Kabelføring

Sofar EMS og Dyness inverterne kommunikerer via RS485 eller Ethernet.

Ethernet

For korrekt ethernet kabelføring: Følg retningslinjerne for ethernet kabelføring.

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
COM6 terminal 1ARS485 ARS485_POSRS485 ATX+
Com6 terminal 1BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Dyness Wiring

Konfiguration

DH100F

Dyness DH100F skal indstilles til fjernbetjeningsmode:

  1. Klik på hovedmenuikonet i øverste højre hjørne af hovedgrænsefladen
  2. Klik på "Data" i hovedmenuen
  3. Klik på "EMS" i undermenuen
  4. Klik på "RunSet" øverst til venstre i navigationsbjælken
  5. Indstil Control Mode til "Remote"
Dyness DH100F Interface
Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

DMEGC Invertere

Previous Page

Dysun Energy

Next Page

On this page

Dyness InvertereUnderstøttede EnhederKabelføringEthernetRS485KonfigurationDH100F