Understøttede enheder
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| H3 (Non-Pro, Non-Smart): → ❗Se note nedenfor ❗ | ❌ | ✅ | ❗(se nedenfor) | Master: 2.05, Manager: 1.85 (*) |
| H3 AIO (All-In-One) | ✅ | ❌ | Master: 1.33, Manager: 1.37 (*) | |
| H3-Smart | ⌛ (under udvikling) | Master: 1.25, Manager: 1.14 (*) | ||
| H3-Pro | Master: 1.62, Manager: 1.34 (*) | |||
| H1 | (eksperimentel, kræver test) | Master: 1.70, Manager: 1.78 (*) | ||
| H1-G2 | ⌛ (under udvikling) | Master: 1.40, Manager: 1.54 (*) | ||
| P3-SH | ✅ (eksperimentel) | ✅ (eksperimentel) | Master: 1.62, Manager: 1.34 (*) |
Forsigtighed
H3 (Non-Pro, Non-Smart)
H3 (Non-Pro, Non-Smart) har forskelligt kommunikationsprotokol afhængigt af inverterens 'master version' og 'manager version'. Vælg den tilsvarende integration baseret på inverterens softwareversioner.
✅ Begrænsning understøttes for firmware versioner master v.2.05 og manager v.1.85 og derunder.
⌛ Begrænsning er under udvikling for firmware versioner master v.2.06 og manager v.1.86 og derover.
Advarsel
H3 (non-pro, non-smart) serien bruger en forskellig kommunikationsprotokol end H3 Pro og H3 Smart serien. Derfor skal du, når du vælger enhedstype i Sofar EMS, være meget sikker på, at du vælger den korrekte type.
Note
Understøttede firmwareversioner
(*) Integration kan fungere med ældre firmwareversioner, men disse er ikke testet.

Kabelføring
Advarsel
Standard modbus adresse eller enheds-ID er 247. Husk dette, når du scanner efter en inverter. Du kan ændre minimum og maksimum bus adresser, som controlleren vil scanne i scanneparametrene.
Ethernet
For korrekt ethernet kabelføring: Følg retningslinjerne for ethernet kabelføring.
Advarsel
Du kan ikke forbinde den via WiFi dongle.
RS485
Inverteren kan forbindes til Sofar EMS via RS485. Dette sker gennem forbindelse [J] på billedet nedenfor.
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | Sofar EMS model OM1 | Sofar EMS model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Logger 485A / pin 1 | RS485 A | RS485_POS | RS485 A | TX+ |
| Logger 485B / pin 2 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |

RS485 H3 Pro
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | Sofar EMS model OM1 | Sofar EMS model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| EMS 485A / pin 17 | RS485 A | RS485_POS | RS485 A | TX+ |
| EMS 485B / pin 18 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |

Konfiguration for H3 (Non-Pro, Non-Smart) og H1-G2
1. Aktivering af overvågning og styring af inverter
Styringen skal aktiveres via inverteren, og måleren skal deaktiveres. Dette gøres via displayet i menuen Feature Parm. Åbn først menuen Feature Parm som følger:
- Gå til Menu.

- Indtast adgangskode. Standard er 0000.

- Vælg Indstillinger.

- Vælg Feature Parm.
2. Aktivering af fjernstyring
Brug displayet videre fra Feature-siden til at aktivere styringen, følg nedenstående trin:
- Vælg Fjernstyring.

- Sæt den til Aktiver.

3. Deaktivering af måler
Måleren skal deaktiveres. Styringen overtages af Sofar EMS. Derfor skal måleren ikke være tilsluttet inverteren, men til Sofar EMS. For at deaktivere måleren i indstillingerne, følg disse trin:
- Gå tilbage til Feature-siden.
- Vælg Meter1.

- Vælg Sæt.

- Sæt den til Deaktiver.

4. Indstilling af inverteradresse
Inverterens adresse kan også indstilles via displayet.
- Gå til Indstillinger-menuen som beskrevet tidligere.
- Vælg Kommunikation.
- Vælg RS485.
- Vælg Enheds-ID.
- Indstil enheds-ID til ønsket adresse. Hvis du forbinder flere enheder til samme RS485 bus, skal hver have en unik adresse.

Tip
Hurtigere scanning
Sofar EMS starter scanningen ved adresse 1 som standard. Hvis du vælger en lavere adresse, vil din inverter blive fundet hurtigere.
Advarsel
Flere invertere
Hvis du har flere invertere, er det vigtigt at sætte parallelle adresser, så hver inverter har en forskellig adresse.
Konfiguration for H3-smart og H3-Pro
Fjernstyring er aktiveret som standard, du behøver ikke ændre indstillinger.
Ændring af inverteradresse (eller enheds-ID) kan gøres på samme måde som for H3 (se ovenfor).