Sofar logo
Sofar logo
AppCertifikater
Eksterne Signaler
EMS
Enheder
Elbilopladningsstation
Energimåler
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
a-TroniXABB, FIMERADS-TecAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid og Batteri InvertereAPsystemsAteps Batteri
Autarco
BattlinkBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid og Batteri InvertereDEYEDiehl-AkoDMEGC InvertereDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UdstyrESY InvertereEVEFairlandFortonaForud for
Foxess
FraxFroniusGoodWeGotionGrønnere / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoveringRitarSAJSchneider SunEzySchucoSCUSE2200H til SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
HYD 3000…6000-ESPowerMagicTL-G3 og TLM/X-G3 Serien
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
EnhederPv Hybrid- og batteri-invertereSofar
logo

Sofar HYD 3000…6000-ES Invertere

Understøttede enheder

Image
Device TypeModbus TCP (Ethernet)RS485Curtailment
Sofar HYD 3000…6000-ES✅ (Solarman WiFi & ethernet dongles)✅❌
Advarsel
Advarsel
  • Det anbefales at bruge RS485, da Solarman-donglen kan ændre firmware og låse Modbus TCP-adgangen!
  • Hvis du bruger en Solarman-dongle, anbefales det at bruge ethernet-donglen for forbindelsesstabilitet.

Kabelføring

Ethernet

For korrekt ethernet-kabelføring: Følg retningslinjerne for ethernet-kabelføring.

Tilslut inverteren til dit internetnetværk ved hjælp af "Solarman-donglen".

  1. Installer WiFi- eller Ethernet-donglen i inverteren og sørg for, at den er tilsluttet dit netværk.
  2. Skriv serienummeret på donglen ned (se billedet til venstre/ovenfor). Det skal du bruge ved opsætning af kommunikationen med controlleren.
Note
Note

Dongle firmware WiFi-dongle firmware LSW3_15_FFFF_1.0.65 og ethernet-dongle firmware ME_08_2701_2.06 er blevet testet. I tilfælde af problemer kan du prøve at lægge disse specifikke firmwareversioner på donglen. Kontakt leverandøren af din dongle for dette.

Image

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
RS485s TX+RS485 ARS485_POSRS485 ATX+
RS485s TX-RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

Konfiguration

Aktivering af ekstern batteristyring

Ekstern batteristyring skal aktiveres i inverterens konfigurationsmenu via LCD-displayet. I inverterindstillingerne:

  1. Gå til "Basic settings".
  2. Gå til "Energy Storage Mode"
  3. Indstil denne til “Set Passive Mode”
  4. For mere information, se Sofar HYD 3000/4000/5000/6000-ES brugermanual side 26 og frem.

RS485

Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Ekstern inverterstyring skal aktiveres i konfigurationsmenuen på inverteren via LCD-skærmen.

  1. Tryk kort på knappen ned.
  2. Du vil se "1. Enter settings", tryk på knappen ned i 2 sekunder for at gå ind i indstillingerne.
  3. Gå igennem indstillingerne, indtil du ser:
    • Modbus Address eller
    • Set ComProtocol
  4. Tryk på knappen ned i 2 sekunder for at indstille adressen.
  5. Indstil adressen til den ønskede værdi.

Sofar

Previous Page

PowerMagic

Next Page

On this page

Sofar HYD 3000…6000-ES InvertereUnderstøttede enhederKabelføringEthernetRS485KonfigurationAktivering af ekstern batteristyringRS485