Solis Grid-Tied Energy Meters
Supported Devices
| Device Type | Modbus TCP (Ethernet) | RS485 |
|---|---|---|
| Solis Grid-Tie Meter (via Inverter/EPM) | ✅ | ✅ |
| Autarco Grid-Tie Meter (via Inverter/EPM) |
Connection
Ethernet
For correct ethernet wiring: Follow the .
Solis Grid-Tied Energy Meters
| Device Type | Modbus TCP (Ethernet) | RS485 |
|---|---|---|
| Solis Grid-Tie Meter (via Inverter/EPM) | ✅ | ✅ |
| Autarco Grid-Tie Meter (via Inverter/EPM) |
For correct ethernet wiring: Follow the .
Connect the RS485 wires to the communication port of the Solis device (Inverter or Export Power Manager).
| Device | Sofar EMS model OM1 | Sofar EMS model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| A | RS485 A | RS485_POS | RS485 A | TX+ |
| B | RS485 B | RS485_NEG | RS485 B | TX- |
| GND (optional) | RS GND | GND | Not available | G |
Ensure the device is configured with the following Modbus settings to match the driver specifications: