Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe Signaleringen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormers
logo

Ondersteunde Apparaten

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Enfase LV Hybride Omvormers Eénfase (SG0XLP1-EU)SUN-3/3.6/5/6/7/7.6/8/10/12K❌✅❌
Enfase LV Hybride Omvormers Driefase (SG0XLP3-EU)SUN-3/4/5/6/8/10/12/14/15/16/18/20K
Enfase HV Hybride Omvormers Driefase (SG0XHP3-EU)SUN-5/6/8/10/12/15/20/25/29.9/30/35/40/50/60/70/75/80K
Enfase Eénfase String Omvormers (G0XP1-EU)SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4/4.2/4.6/5/5.2/6/6.2/7/7.5/8/9/10/10.5K
Enfase Driefase String Omvormers (G0XP3-EU)SUN-3/4/5/6/7/8/9/10/12/15/18/20/22/23/25/30/35/36/40/45/50/60/70/75/80/90/100/120/125/130/135/136K

Bekabeling

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Image 1
Image 1
Image 1

Configuratie

Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Ga naar "Hoofdscherm" >> "Systeeminstellingen" >> "Geavanceerde Functie."

  • Modbus SN moet worden ingesteld op een getal tussen 1 en 247. Selecteer geen 0!! Let op dat als er meerdere apparaten op de RS485-bus zijn, elk een uniek nummer moet krijgen. Dit is het adres.
  • Slave moet aangevinkt zijn.
  • Alleen wanneer een extra meter rechtstreeks op de omvormer is aangesloten, moet “EX_meter For CT” aangevinkt zijn. Als er slechts een meter parallel met de Sofar EMS zit, moet het niet aangevinkt zijn.
  • Zorg dat de volgende instellingen allemaal correct zijn: "Max A Laden", "Max A Ontladen", "Netlaad Ampère"
Image 1

DET Power PV-, Hybride- en Batterijomvormers

Previous Page

Diehl-Ako

Next Page

On this page

Ondersteunde ApparatenBekabelingRS485Configuratie