Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe Signaleringen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormers
Dysun Energy

Ondersteunde Apparaten

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Hybride omvormerDysun Hybrid✅✅❌
FlexAmpFlexAmp One 3.6K, FlexAmp One 5K❌✅

Bekabeling

Modbus TCP

  • Sluit de LAN-poort van de omvormer aan op uw lokale netwerk.
  • Standaard poort: 502.
  • De Modbus unit ID moet worden ingesteld tussen 1–247 (standaard 1).

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Seriële instellingen:

  • Baudrate: 9600 (standaard) of zoals ingesteld in het omvormermenu
  • Databits: 8
  • Pariteit: Geen
  • Stopbits: 1

Configuratie

Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.
  • Stel het Modbus-adres (slave ID) in tussen 1–247 in het omvormermenu.
  • Elk apparaat op de RS485-bus moet een uniek adres hebben.
  • Voor best practices van RS485 bekabeling, zie de Bekabelingsrichtlijnen.

FlexAmp Serie Configuratie

Tijdens het scannen van apparaten of handmatige configuratie wordt u gevraagd:

"Wat is inbegrepen in de installatie?"

  • Zonnepanelen en batterij (standaard)
  • Alleen zonnepanelen
  • Alleen batterij

Selecteer de optie die overeenkomt met uw installatie om correcte apparaatdetectie en monitoring te waarborgen.

Besturing

Dysun Hybrid

De omvormer ondersteunt batterijbesturing:

  • Laadmodus: Stel laadstroom in ampères in
  • Ontlaadmodus: Stel ontlaadvermogen in als percentage
  • Wanneer besturing is uitgeschakeld, keert de omvormer terug naar autonome werking
Let op
Let op

Experimenteel Besturingsfuncties voor Dysun Hybrid zijn niet gevalideerd op live hardware.