Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe Signaleringen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormers
logo

Dyness Omvormers

Belangrijk
Belangrijk

Momenteel wordt de integratie ondersteund tot een laadstatuslimiet van 95%. Dit komt omdat wanneer de laadstatus boven de 95% uitkomt, de batterij kan stoppen met reageren op setpoints vanwege de acties van het batterijsysteembeheer. We zijn bezig dit probleem op te lossen met Dyness en andere partners.

Ondersteunde apparaten

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
EC100100kWh✅✅✅
DH100F71~100kWh
DH200F100kW/215kWh
DH200Y100kW/232kWh❌

Bekabeling

De Sofar EMS en de Dyness omvormers communiceren via RS485 of Ethernet.

Ethernet

Voor correcte ethernetbekabeling: volg de de richtlijnen voor ethernetbekabeling.

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
COM6 terminal 1ARS485 ARS485_POSRS485 ATX+
Com6 terminal 1BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Dyness Wiring

Configuratie

DH100F

De Dyness DH100F moet worden ingesteld op afstandsmodus:

  1. Klik op het hoofdmenu-icoon rechtsboven in de hoofdinterface
  2. Klik op "Data" in de hoofdnavigatiebalk
  3. Klik op "EMS" in de submenu-balk
  4. Klik linksboven in de navigatiebalk op "RunSet"
  5. Stel de besturingsmodus in op "Remote"
Dyness DH100F Interface
Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

DMEGC Omvormers

Previous Page

Dysun Energy

Next Page

On this page

Dyness OmvormersOndersteunde apparatenBekabelingEthernetRS485ConfiguratieDH100F