Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FoxESS GMAXFoxESS H-SerieFoxESS R-Serie
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe Signaleringen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormersFoxess
logo

Ondersteunde Apparaten

Device TypeModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
H3 (Non-Pro, Non-Smart): → ❗Zie opmerking hieronder ❗❌✅❗(zie hieronder)Master: 2.05, Manager: 1.85 (*)
H3 AIO (All-In-One)✅❌Master: 1.33, Manager: 1.37 (*)
H3-Smart⌛ (in ontwikkeling)Master: 1.25, Manager: 1.14 (*)
H3-ProMaster: 1.62, Manager: 1.34 (*)
H1(experimenteel, vereist testen)Master: 1.70, Manager: 1.78 (*)
H1-G2⌛ (in ontwikkeling)Master: 1.40, Manager: 1.54 (*)
P3-SH✅ (experimenteel)✅ (experimenteel)Master: 1.62, Manager: 1.34 (*)
Let op
Let op

H3 (Non-Pro, Non-Smart)

De H3 (Non-Pro, Non-Smart) gebruikt een verschillend communicatieprotocol afhankelijk van de 'master versie' en 'manager versie' van de omvormer. Kies de bijbehorende integratie op basis van de softwareversies van de omvormer.

✅ Curtailment wordt ondersteund voor Firmwareversies master v.2.05 en manager v.1.85 en lager.

⌛ Curtailment is in ontwikkeling voor Firmwareversies master v.2.06 en manager v.1.86 en hoger.

Waarschuwing
Waarschuwing

De H3 (non-pro, non-smart) serie gebruikt een anders communicatieprotocol dan de H3 Pro en H3 Smart serie. Daarom moet u bij het selecteren van het apparaattype in de Sofar EMS zeer zeker zijn dat u het juiste type kiest.

Opmerking
Opmerking

Ondersteunde Firmwareversies

(*) De integratie kan werken voor oudere firmwareversies, maar deze zijn niet getest.

Image 1

Bekabeling

Waarschuwing
Waarschuwing

Het standaard modbusadres, of apparaat-ID, is 247. Houd hier rekening mee bij het scannen van een omvormer. U kunt de minimale en maximale busadressen die de controller scant aanpassen in de scanparameters.

Ethernet

Voor correcte ethernetbekabeling: Volg de richtlijnen voor ethernetbekabeling.

Waarschuwing
Waarschuwing

U kunt het niet verbinden via de WiFi-dongle.

RS485

De omvormer kan via RS485 worden aangesloten op de Sofar EMS. Dit gebeurt via aansluiting [J] in de onderstaande afbeelding.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
Logger 485A / pin 1RS485 ARS485_POSRS485 ATX+
Logger 485B / pin 2RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

RS485 H3 Pro

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
EMS 485A / pin 17RS485 ARS485_POSRS485 ATX+
EMS 485B / pin 18RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

Configuratie voor H3 (Non-Pro, Non-Smart) en H1-G2

1. Activeren monitoring & beheer omvormer

De regeling moet geactiveerd worden via de omvormer en de meter moet gedeactiveerd zijn. Dit gebeurt via het display in het menu Feature Parm. Open eerst het Feature Parm menu als volgt:

  1. Ga naar het Menu.
Image 1
  1. Voer het wachtwoord in. De standaardwaarde is 0000.
Image 1
  1. Selecteer Instellingen.
Image 1
  1. Selecteer Feature Parm.

2. Activeren van afstandsbediening

Gebruik het display op de Feature-pagina om de regeling te activeren, volg de stappen hieronder:

  1. Selecteer Afstandsbediening.
Image 1
  1. Zet deze op Inschakelen.
Image 1

3. Meter deactiveren

De meter moet gedeactiveerd worden. De regeling wordt overgenomen door de Sofar EMS. Daarom moet de meter niet op de omvormer, maar op de Sofar EMS worden aangesloten. Volg de onderstaande stappen om de meter in de instellingen uit te schakelen:

  1. Ga terug naar de Feature-pagina.
  2. Selecteer Meter1.
Image 1
  1. Selecteer Instellen.
Image 1
  1. Zet deze op Uitschakelen.
Image 1

4. Instellen van omvormeradres

Het adres van de omvormer kan ook via het display worden ingesteld.

  1. Ga naar het Instellingen-menu zoals hierboven beschreven.
  2. Selecteer Communicatie.
  3. Selecteer RS485.
  4. Selecteer Apparaat-ID.
  5. Stel de apparaat-ID in op het gewenste adres. Als u meerdere apparaten op dezelfde RS485-bus aansluit, moet elk een uniek adres krijgen.
Image 1
Tip
Tip

Sneller scannen

De Sofar EMS begint standaard te scannen vanaf adres 1. Het kiezen van een lager adres zorgt ervoor dat uw omvormer sneller wordt gevonden.

Waarschuwing
Waarschuwing

Meerdere omvormers

Als u meerdere omvormers heeft, is het belangrijk om parallelle adressen in te stellen; elke omvormer moet een verschillend adres hebben.

Configuratie voor H3-smart en H3-Pro

Afstandsbediening staat standaard aan, u hoeft geen instellingen te wijzigen.

Het wijzigen van het omvormeradres (of apparaat-ID) kan op dezelfde manier als bij de H3 (zie hierboven).

FoxESS GMAX

Previous Page

FoxESS R-Serie

Next Page

On this page

Ondersteunde ApparatenH3 (Non-Pro, Non-Smart)Ondersteunde FirmwareversiesBekabelingEthernetRS485RS485 H3 ProConfiguratie voor H3 (Non-Pro, Non-Smart) en H1-G21. Activeren monitoring & beheer omvormer2. Activeren van afstandsbediening3. Meter deactiveren4. Instellen van omvormeradresSneller scannenMeerdere omvormersConfiguratie voor H3-smart en H3-Pro