Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Alles-in-één ESSHybride Omvormers
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe Signaleringen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormersHyxipower
logo

Ondersteunde Apparaten

Device TypeVariantsManualModbus TCP (Ethernet)RS485Curtailment
Hybrid inverter InverterHYX-H5K-HTManual❌✅✅
HYX-H6K-HT
HYX-H8K-HT
HYX-H10K-HT
HYX-H12K-HT
HYX-H15K-HTManual
HYX-H20K-HT
HYX-H25K-HT

Bekabeling

RS485

Voor RS485-bekabeling, gebruik de gereserveerde communicatiepoort (N° 14) op de omvormer.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSofar EMS model OM1Sofar EMS model IG8RS485-USB converterRS485-Ethernet converter
RS485 A (Pin 5)RS485 ARS485_POSRS485 ATX+
RS485 B (Pin 6)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

Alles-in-één ESS

Previous Page

iWell

Next Page

On this page

Ondersteunde ApparatenBekabelingRS485