Sofar logo
Sofar logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BattlinkBeauventC-BatterijCelvermogenChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
KSTAR BluE-S Serie (Gen 1)KSTAR BlueSpark Serie (Gen 2)KSTAR C&I Hybride Omvormers
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
EMS
Externe signalen
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
RegeltijdSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingen
ApparatenPv hybride- en batterijomvormersKstar
logo

KSTAR C&I Hybride Omvormers

Ondersteunde Apparaten

Device TypeVariantsModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
BluePulse Hybrid InverterKAC50DP-BC100DE✅✅✅V000B060D000
KAC50DP-BC107DE / KAC50DP-BC107DE2
KAC50DP-BC197DE / KAC50DP-BC197DE2
BC100DE battery cabinet
BC70DE2/BC89DE2/BC107DE2 battery cabinet
BC197DE2/BC215DE2/BC233DE2 battery cabinet

Bekabeling

De Sofar EMS en de KSTAR omvormers communiceren via Ethernet of RS485.

Ethernet

TCP connection diagram

Voor correcte ethernetbekabeling: volg de richtlijnen voor ethernetbekabeling.

RS485

RS485 connection diagram

Configuratie

Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The Sofar EMS will scan on those first.

KSTAR BlueSpark Serie (Gen 2)