In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| ALP EV EVC10 DUO | Two-connector monitoring; single-vehicle charging control | One-vehicle charging observed; simultaneous two-vehicle control unsupported |
See integration details for connection requirements and operating limitations.
A custom integration monitors both connectors of the EVC10 DUO. Charging control has been observed with one vehicle. An idle-current correction maintains 6 A when neither connector has a vehicle.
Simultaneous control of two vehicles is not supported by this variant: the second connector's independent current-control mapping remains unresolved, so the driver requests zero current when both vehicles are connected. A charging session following the idle-current change still needs validation.