Connect to your computer in the same LAN network as the charging station, and surf to the charging station's IP address.
Log into the charging station's local web interface (default login "operator", password "service.kraft"), and go to the "Load Management" tab.
Fill this out exactly as shown in the image on the below and click save.
Warning
Warning
Please note:
Different configurations from the indicated image have not been tested.
In all cases, you must turn on the Modbus TCP server, leave the base port at 502 and set the register address group to TQ-DM100.
If you activate SEMP interface, EEBUS, Dynamic Load Management or ASKI via OCPP-S, it may interfere with the control of the EMS. It is strongly discouraged to activate these functions.