In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| KEBA P30 c-series / x-series | Modbus TCP monitoring and current control | c-series firmware 3.10.74 checked; vehicle charging/resume test required |
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| KEBA P40 / P40 Pro | Separate implementation candidates | Technical assessment and version preparation required; P30 evidence does not validate P40 |
See integration details for connection requirements and operating limitations.
A custom Modbus TCP integration supports the P30 c-series/x-series protocol from firmware 3.10.16. Enable the Modbus interface with DSW1.3 and avoid simultaneous UDP control. A c-series device with firmware 3.10.74 has been used for verification.
The implementation monitors charging and controls current, suspending requests below 6 A. Vehicle charging, pause/resume and installation limits must be checked during commissioning.
An earlier implemented candidate remains available for technical assessment on request. Its earlier review was closed; Eniris must review and prepare the appropriate version before installation. It is not a ready-to-install standard release. P40 and P40 Pro implementation candidates exist separately from the P30 custom driver. The P30 hardware evidence does not validate P40 operation.