In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| Teison Pro DC, 90 kW split stack | V1.3 Modbus TCP, port 5020; total-stack power request | Reads checked; competing control and fallback must be resolved |
See integration details for connection requirements and operating limitations.
A custom integration targets the split-stack V1.3 protocol over Modbus TCP port 5020, device number 1. Live reads verified the literal register addressing used by this stack. The available command controls the total stack power, not each connector independently.
Another control path was observed overwriting the power limit. Resolve competing control before testing EMS commands. There is no confirmed communication timeout for this limit; the stack may retain the last value. Other stack numbers and protocol variants require separate mapping and validation.