In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| smart-me Pico, 22 kW | Modbus TCP monitoring, current control and phase requests | Firmware 0.0.53+; phase-switching wait correction and physical test required |
See integration details for connection requirements and operating limitations.
A custom Modbus TCP integration provides metering, current limits, pause and single-/three-phase requests for Pico. The control interface requires firmware 0.0.53 or newer.
Pico requires a ten-minute wait before switching back from one to three phases. A correction implementing that wait has been prepared and validated with the driver engine, but it had not yet been installed for the physical test. Do not enable automatic phase switching without that correction and a successful commissioning test.