In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| Mennekes AMTRON HCC3 / Xtra E 22 C2 | Current control in Remote mode | Writes checked without vehicle; charging/resume test required |
See integration details for connection requirements and operating limitations.
| Device Type | Modbus TCP (Ethernet) | RS485 |
|---|---|---|
| Amtron EV charger | ✅ | ✅ |
In the application, go to your device, then "Settings".
Go in the "Connection" tab to enable Modbus TCP, and set the Modbus TCP server to "Read and Write" mode (HEMS Read and Write). In "Read only" mode the EMS can read the charger's data but cannot control its charging current.
Give the charger a fixed IP address in the same network as the EMS.
Custom current control is available in Remote mode. Setpoint writes for charging, pause and release were checked without a connected vehicle. A complete vehicle charging and resume test remains necessary.