In beta and available on request. The additions in this overview require the matching integration or controller update and are not confirmed as part of the standard customer release. Request them through your existing Eniris support conversation. The status applies to these additions, not to every existing function of the devices listed elsewhere on this page.
| Model / system | Beta addition | Validation and conditions |
|---|---|---|
| Afore AF15K-TH, protocol v3.4 | External command mode | Discharge and zero-power release checked; charge and sustained operation pending |
See integration details for connection requirements and operating limitations.
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Reactive power control |
|---|---|---|---|---|
| Single Phase (1-3kW) | ❌ | ✅ | ❌ | — |
| Single Phase (3-6kW) | ||||
| Single Phase (7-10kW) | ||||
| Three Phase (3-25kW) | ||||
| Three Phase (30kW) | ||||
| Three Phase (36-60kW) | ||||
| Three Phase (70-110kW) |
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Reactive power control |
|---|---|---|---|---|
| AF1-3.6K-SL-1 | ❌ | ✅ | ❌ | — |
| AF3-3.6K-SL | ||||
| AF4-6K-SLP | ||||
| AF1-6K-SL-0 | ||||
| AF3-9.6K-DH | ||||
| AF3-15K-MTH | ||||
| AF3-30K-TH | ||||
| AF36-50K-TH | ||||
| AF3-12K-THP | ||||
| AF3-30K-TH-0 | ||||
| AF3-12K-THP-0 |
Power On the Inverter
Navigate to the Main Menu
Enter the Settings Menu
Find Communication Options
Set Communication Protocol
Adjust Communication Parameters
| Parameter | Value |
|---|---|
| Baud Rate | 9600 or 19200 bps |
| Parity | None or Even |
| Data Bits | 8 |
| Stop Bits | 1 |
Assign Modbus Address
A custom protocol-v3.4 implementation corrects external command-mode handling. Zero-power release and discharge response have been checked on the AF15K-TH; charging and sustained normal-controller operation remain to be validated. Existing inverter, battery and grid limits must be retained.