| Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
|---|
| Angile | AE10K-H-T | ❌ | ✅ |
| AESCB20 |
| AES5.1-M |
To connect te Angile to RS485 you need to connect it through the D-B/485 port on the inverter.
InfoRS485 Wiring
- For correct RS485 wiring: follow the RS485 wiring guidelines.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general industry consensus on the use of A and B for RS485 polarity, so the naming may be counterintuitive for some devices.
WarningNOTE: RS485 Device Addresses
- You MUST give each device a unique address on the RS485 bus. Check the device manual for instructions.
- Use lower addresses first (1, 2, ...) because the Sofar EMS will find them faster!
- For each device, it is generally recommended to keep the factory-default baud rate, parity, and stop bits. The Sofar EMS will scan those first.